BoredAviator
Fire Protection
QRH 8.32 · Étape 6
6 Engine BLEED air switches (both) → Verify ON
Set thrust to maximum practical N1 (minimum 45%).
Open flight deck air conditioning and gasper outlets.
CAUTION — Do not open any flight deck window. Keep the flight deck door closed.

Choisis une option

Smoke or fumes are controllable→ Smoke, Fire or Fumes 8.21 remaining steps Smoke or fumes are uncontrollable→ Descend to lowest safe altitude or 10,000 feet
Descend to the lowest safe altitude or 10,000 feet, whichever is higher.
When at 14,000 feet or below:
Pressurization mode selector → MAN
Outflow VALVE switch → Hold in OPEN until the outflow VALVE indication shows fully open
This causes the cabin airflow to carry smoke or fumes aft. NOTE: The outflow valve can take up to 20 seconds to open.
Smoke, Fire or Fumes remaining steps→ QRH 8.21
← Retour au début QRH officiel AILO-0902 (PDF)