QRH 8.32 · Étape 6
6 Engine BLEED air switches (both) → Verify ON
Set thrust to maximum practical N1 (minimum 45%).
Open flight deck air conditioning and gasper outlets.
CAUTION — Do not open any flight deck window. Keep the flight deck door closed.
Choisis une option
Descend to the lowest safe altitude or 10,000 feet, whichever is higher.
When at 14,000 feet or below:
Pressurization mode selector → MAN
Outflow VALVE switch → Hold in OPEN until the outflow VALVE indication shows fully open
This causes the cabin airflow to carry smoke or fumes aft. NOTE: The outflow valve can take up to 20 seconds to open.
← Retour au début
QRH officiel AILO-0902 (PDF)