Air Inuit SOP B73C · AILO-0022.7 · Amendment 2 · 15 déc 2025
First flight of the day: full checklist. Subsequent flights: items marked * only. Complete "To the Line" when fueling done, W&B complete, Ground Conditioned Air disconnected. Below the line when start/pushback clearance received.
PIC
Request Before Start Checklist to the line.
Parking Brake …… ON
Fuel Panel …… Set
If CTR tank > 1500 kg: L & R CTR FUEL PUMPS …… ON
• If LOW PRESSURE stays on → OFF
If CTR 500–1500 kg: L & R CTR ON then OFF after LP lights out
AFT and FWD FUEL PUMPS …… ON
Hydraulic Panel …… Set
A PUMPS As needed · B PUMPS ON
Below the line: Side Window Closed & Secure · DEFOCS Received
SIC
APU Bleed …… ON
PACKs (Both) …… ON
Read items to the line · announce complete
Below the line:
Side Window Closed & Secure
Doors / MCD (3) Lights out
ANTI COLLISION …… ON
Transponder …… ALT OFF
Read below the line · announce complete