BoredAviator
Engines, APU
QRH 7.15
Condition
Un EEC fonctionne en mode de commande alternate.
1 Autothrottle (if engaged) → Disengage
2 Thrust levers (both) → Retard to mid position This prevents exceeding thrust limits when switching to the EEC alternate mode
3 EEC mode switches (one at a time) → ALTN This ensures both engines operate in alternate mode
4 Autothrottle (if needed) → Engage
NOTE — Maximum thrust limiting is available with autothrottle engaged. Do not exceed engine limits. Engine limit protection in alternate mod is not the same as in normal mode.

Choisis une option

DSPLY SOURCE 1 or DSPLY SOURCE 2→ Étape 7 DSPLY SOURCE 1 and DSPLY SOURCE 2✓ Fin de checklist
QRH officiel AILO-0902 (PDF)