Mode hors ligneOffline
BoredAviator
Communications
SYS
ConditionCondition
ACARS inopérant — MU Fail (Management Unit) ou DU Fail (Display Unit dédié).ACARS inoperative — MU Fail (Management Unit) or DU Fail (dedicated Display Unit).
ObjectifObjective
Choisir le bon reset CB (MU ~10 s vs DU ~60 s) et relier au MEL 23-09 / fuel schemes.Choose the correct CB reset (MU ~10 s vs DU ~60 s) and tie to MEL 23-09 / fuel schemes.
MU vs DU — DÉFINITIONS
MU FAIL
DU FAIL
MU CB ~ 10 s DU CB ~ 60 s
Temps de reset — ne pas inverser MU/DU.Reset times — do not swap MU/DU.
SymptomCheck firstCB action
MU FAIL / random text—MU CB ~10 s
DU blankBrightness · DU CB statusas needed
Touch deadDirty / wet screen?DU CB ~60 s
DISPATCH · FUEL SCHEMES
POINTS CLÉSKEY POINTS
Après reset CB, re-vérifier LINK STATUS (NO COMM page) avant de conclure MU mort.After CB reset, re-check LINK STATUS (NO COMM page) before concluding MU is dead.
FLUX TEACHINGTEACHING FLOW
Symptom → MU or DU? → CB reset → MEL? Then re-check LINK STATUS · fuel scheme if still out
Flux : symptôme → MU/DU → reset → MEL/fuel.Flow: symptom → MU/DU → reset → MEL/fuel.
RefValue
MEL ACARS23-09
MEL Printer23-09-01
MU reset~10 s
DU touch reset~60 s
Si MU/DU restent morts après reset → traiter comme ACARS System MEL 23-09 et revoir fuel scheme (Following si SATCOM aussi out).If MU/DU stay dead after reset → treat as ACARS System MEL 23-09 and revisit fuel scheme (Following if SATCOM also out).